DTC B1176: Fuel Level Sensor (Fuel Gauge Sending Unit) Circuit Short (Without SH-AWD)

DTC Description DTC
B1176 Fuel Level Sensor (Fuel Gauge Sending Unit) Circuit Short  

NOTE:  If you are troubleshooting multiple DTCs, be sure to follow the instructions in B-CAN System Diagnosis Test Mode A - Refer to: Body Electrical Troubleshooting - B-CAN System Diagnosis Test Mode A - Initial Communication and DTC Checks (2015-17), or Body Electrical Troubleshooting - B-CAN System Diagnosis Test Mode A - Initial Communication and DTC Checks (2018-19) .

DTC (Gauge Control Module)

  1. Problem verification

    -1. Check the fuel gauge.

    Does the gauge move to the full position and the low fuel indicator blink?

    YES 

    Go to step 2.

    NO 

    Intermittent failure, the system is OK at this time. Check for loose or poor connections.

  2. Fuel gauge operation check 1

    -1. Turn the vehicle to the OFF (LOCK) mode.

    - 2. Disconnect the following connector.

    Fuel tank unit 4P connector

    - 3. Turn the vehicle to the ON mode.

    - 4. Check the fuel gauge.

    Does the gauge move to the empty position?

    YES 

    Faulty the fuel gauge sending unit, replace the fuel tank unit - Refer to: Fuel Tank Unit Removal and Installation (With SH-AWD), or Fuel Tank Unit Removal and Installation (Without SH-AWD) .

    NO 

    Go to step 3.

  3. Shorted wire check (FUEL GAUGE+ line)

    -1. Turn the vehicle to the OFF (LOCK) mode.

    - 2. Disconnect the following connector.

    Gauge control module 32P connector

    - 3. Check for continuity between test points 1 and 2.

    Test condition Vehicle OFF (LOCK) mode

    Fuel tank unit 4P connector: disconnected

    Gauge control module 32P connector: disconnected

    Test point 1 Gauge control module 32P connector No. 6 - Refer to: Gauge Control Module Input Test (2015-17), or Gauge Control Module Input Test (2018-19)
    Test point 2 Body ground

    Is there continuity?

    YES 

    Repair a short to ground in the wire between the gauge control module and the fuel tank unit.

    NO 

    The FUEL GAUGE+ wire is OK. Replace the gauge control module .