LEMON Manuals: Even more car manuals for everyone
Home >> Acura >> 2020 >> ILX >> Repair and Diagnosis >> External Pages >> Different car >> Section 131 (VSA System - DTC Diagnostics (Except Hybrid)) >> DTC Troubleshooting >> DTC U3006-13 (VSA Control Unit)

DTC U3006-13 (VSA Control Unit)

WARNING: This page is about a different car, the 2022 Honda Accord, 2021 Honda Accord, 2020 Honda Accord, 2019 Honda Accord, and 2018 Honda Accord. However, it is still accessible from the selected car via links, so may be relevant.

DTC U3006-13  : IG1 Circuit Open

NOTE: Before you troubleshoot, review the general troubleshooting information.

DTC Description DTC
U3006-13 IG1 Circuit Open  

DTC (VSA)

  1. Problem verification

    -1. Turn the vehicle to the ON mode.

    -2. Clear the DTC with the HDS.

    -3. Turn the vehicle to the OFF (LOCK) mode, then to the ON mode.

    -4. Check for DTCs with the HDS.

    DTC Description DTC
    U3006-13 IG1 Circuit Open  

    Is DTC U3006-13 indicated?

    YES 

    The failure is duplicated. Go to step 2.

    NO 

    Intermittent failure, the system is OK at this time. Refer to intermittent failures troubleshooting .

  2. Fuse check

    -1. Turn the vehicle to the OFF (LOCK) mode.

    -2. Check the following fuse.

    Fuse No. A41

    Is the fuse OK?

    YES 

    The fuse is OK. Reinstall the fuse, then go to step 3.

    NO 

    Replace the fuse. Turn the vehicle to the ON mode, then to the OFF (LOCK) mode. If the fuse blows again, repair a short to body ground in the No. A41 fuse circuit.

  3. Open wire check (IG1 ABS/VSA (or IG1 VSA/ABS) line)

    -1. Disconnect the following connector.

    VSA modulator-control unit 46P connector

    -2. Turn the vehicle to the ON mode.

    -3. Measure the voltage between test points 1 and 2.

    Test condition Vehicle ON mode
      VSA modulator-control unit 46P connector: disconnected
    Test point 1 VSA modulator-control unit 46P connector No. 13
    Test point 2 Body ground

    Is there battery voltage?

    YES 

    Check for loose terminals and poor connections in the VSA modulator-control unit 46P connector. Check for any authorized service information related to the DTCs or symptoms you are troubleshooting. If they are OK, replace the VSA modulator-control unit .

    NO 

    Repair an open in the wire between the VSA modulator-control unit 46P connector and the No. A41 fuse.