DTC U3003-68 (VSA Control Unit)
DTC U3003-68 : Electric Parking Brake Control Unit Internal Circuit Malfunction (Power Self-Holding Circuit)
NOTE: Before you troubleshoot, review the general troubleshooting information.
| DTC Description | DTC |
|---|---|
| U3003-68 Electric Parking Brake Control Unit Internal Circuit Malfunction (Power Self-Holding Circuit) |
DTC (VSA)
- Problem verification
-1. Turn the vehicle to the ON mode.
-2. Clear the DTC with the HDS.
-3. Turn the vehicle to the OFF (LOCK) mode, then to the ON mode.
-4. Apply and release the parking brake several times.
-5. Check for DTCs with the HDS.
DTC Description DTC U3003-68 Electric Parking Brake Control Unit Internal Circuit Malfunction (Power Self-Holding Circuit) Is DTC U3003-68 indicated?
YES
The failure is duplicated. Go to step 2.
NO
Intermittent failure, the system is OK at this time. Refer to intermittent failures troubleshooting .
- Fuse check
-1. Turn the vehicle to the OFF (LOCK) mode.
-2. Check the following fuse.
Fuse No. A2-3 Are the fuses OK?
YES
The fuse is OK. Reinstall the fuse, then go to step 3.
NO
Replace the fuse. If the fuse blows again, repair a short to body ground in the No. A2-3 fuse circuit.
- Open wire check (+B ABS/VSA FSR line)
-1. Disconnect the following connector.
VSA modulator-control unit 46P connector -2. Measure the voltage between test points 1 and 2.
Test condition Vehicle OFF (LOCK) mode VSA modulator-control unit 46P connector: disconnected Test point 1 VSA modulator-control unit 46P connector No. 1 Test point 2 Body ground Is there battery voltage?
YES
The +B ABS/VSA FSR wire is OK. Go to step 4.
NO
Repair an open or high resistance in the wire between the VSA modulator-control unit 46P connector and the No. A2-3 fuse.
- Open wire check (GND line)
-1. Check for continuity between test points 1 and 2.
Test condition Vehicle OFF (LOCK) mode VSA modulator-control unit 46P connector: disconnected Test point 1 VSA modulator-control unit 46P connector No. 4 Test point 2 Body ground Is there continuity?
YES
Check for loose terminals and poor connections in the VSA modulator-control unit 46P connector. Check for any authorized service information related to the DTCs or symptoms you are troubleshooting. If they are OK, replace the VSA modulator-control unit .
NO
Repair an open in the wire between the VSA modulator-control unit and body ground (G401).