Back-Up Light Switch Test
WARNING: This page is about a different variant/trim than selected.
- Disconnect the back-up light switch 2P connector (A).
- Check for continuity between back-up light switch 2P connector terminals No. 1 and No. 2. There should be continuity only when the shift lever is in reverse.
- If the test result is OK, go to step 5.
- If the test result is not OK, go to step 3.
- Remove the back-up light switch (A). Check for continuity between back-up light switch 2P connector terminals No. 1 and No. 2. There should be continuity when the switch end (B) is pressed, and no continuity when the switch end is released.
- If the test result is OK, check the reverse shift mechanism in the transmission.
- If the test result is not OK, replace the back-up light switch.
Courtesy of AMERICAN HONDA MOTOR CO., INC.
- Apply liquid gasket (P/N 08717-0004, 08718-0001, 08718-0012, 08718-0003, or 08718-0009) to the threads of the back-up light switch, and install it on the transmission housing.
- Connect the back-up light switch 2P connector.