Oil Pump Inspection
NOTE:
Refer to the Exploded View if needed during this procedure.
- Remove the pump housing.
- Align the tip of the inner rotor tooth (A) with the mark (B) on the outer rotor, then check the inner rotor-to-outer rotor radial clearance between the inner rotor and the outer rotor. If the inner rotor-to-outer rotor radial clearance exceeds the service limit, replace the oil pump.
Inner Rotor-to-Outer Rotor Radial Clearance
Standard (New): 0.05-0.15 mm (0.0020-0.0059 in)
Service Limit: 0.19 mm (0.0075 in)
- Check the pump housing-to-rotor axial clearance between the rotor (A) and the pump housing (B). If the pump housing-to-rotor axial clearance exceeds the service limit, replace the oil pump.
Pump Housing-to-Rotor Axial Clearance Standard (New): 0.035-0.070 mm (0.00138-0.00276 in)
Service Limit: 0.12 mm (0.0047 in)
- Check the pump housing-to-outer rotor radial clearance between the outer rotor (A) and the pump housing (B). If the pump housing-to-outer rotor radial clearance exceeds the service limit, replace the oil pump.
Pump Housing-to-Outer Rotor Radial Clearance
Standard (New): 0.15-0.21 mm (0.0059-0.0083 in)
Service Limit: 0.23 mm (0.0091 in)