DTC U1286: Gauge Control Module Lost Communication With Keyless Access Control Unit
- Clear the DTCs with the HDS.
- Turn the ignition switch to LOCK (0) and then back to ON (II), or press the engine start/stop button to select the OFF mode and then the ON mode.
- Wait for at least 6 seconds.
- Check for DTCs with the HDS.
Is DTC U1286 indicated?
YES -Go to step 5.
NO -Intermittent failure, the system is OK at this time. Check for loose or poor connections between the gauge control module and the keyless access control unit.
- From the BODY ELECTRICAL SYSTEM SELECT menu, select B-CAN CONTROL UNITS INFORMATION, and then select CHECK CONNECTED CONTROL UNITS.
Is the keyless access control unit detected?
YES -Go to step 9.
NO -Go to step 6.
- Measure the voltage between body ground and keyless access control unit connector B (32) terminals No. 1 and No. 17 individually.Fig 1: Measuring Voltage Between Body Ground And Keyless Access Control Unit Connector B (32) Terminals No. 1 And No. 17
Courtesy of AMERICAN HONDA MOTOR CO., INC.
Is there battery voltage?
YES -Go to step 8.
NO -Go to step 7.
- Check the No. 15 (10 A) fuse in the under-hood fuse/relay box and the No. 9 (20 A) fuse in the driver's under-dash fuse/relay box.
Are the fuses OK?
YES -Repair an open or high resistance in the No. 15 (10 A) and/or No. 9 (20 A) fuse circuit.
NO -Replace the fuse(s). If the fuse blows again, repair a short to ground in the No. 15 (10 A) and/or No. 9 (20 A) fuse circuit.
- Measure the voltage between body ground and keyless access control unit connector A (36P) and B (32P) terminals as shown.
Keyless access control unit connector A36 Body ground B32 Fig 2: Measuring Voltage Between Body Ground And Keyless Access Control Unit Connector A (36P) TerminalsCourtesy of AMERICAN HONDA MOTOR CO., INC.
Fig 3: Measuring Voltage Between Body Ground And Keyless Access Control Unit Connector B (32P) TerminalsCourtesy of AMERICAN HONDA MOTOR CO., INC.
Is there less than 0.2 V?
YES -Go to step 9.
NO -Repair an open or high resistance in the ground wire or poor ground (G402).
- Turn the ignition switch to LOCK (0), or press the engine start/stop button to select the OFF mode.
- Disconnect keyless access control unit connector B (32P).
- Disconnect the gauge control module 32P connector.
- Check for continuity between keyless access control unit connector B (32P) terminals No. 7 and No. 8 and gauge control module 32P connector terminals No. 29 and No. 30 respectively.Fig 4: Checking Continuity Between Keyless Access Control Unit Connector B (32P) And Gauge Control Module 32P Connector
Courtesy of AMERICAN HONDA MOTOR CO., INC.
Is there continuity?
YES -Replace the gauge control module (see GAUGE CONTROL MODULE REPLACEMENT ).
NO -Repair an open or poor connection in the B-CAN wire between the gauge control module and keyless access control unit.