DTC B1175: Fuel Level Sensor (Fuel Gauge Sending Unit) Circuit Malfunction
- Clear the DTCs with the HDS.
- Turn the ignition switch to LOCK (0) and then back to ON (II), or press the engine start/stop button to select the OFF mode and then the ON mode.
- Wait at least than 30 seconds.
- Check for DTCs with the HDS.
Is DTCs B1175 indicated?
YES -
- Without SH-AWD: Go to step 5.
- With SH-AWD: Go to step 10.
NO -Intermittent failure, the system is OK at this time. Check for loose or poor connections.
- Turn the ignition switch to LOCK (0), or press the engine start/stop button to select the OFF mode.
- Disconnect the fuel gauge sending unit 4P connector.
- Disconnect the gauge control module 32P connector.
- Check for continuity between gauge control module 32P connector terminals No. 2 and No. 4 and fuel gauge sending unit 4P connector terminals No. 3 and No. 1 respectively.Fig 1: Checking Continuity Between Gauge Control Module 32P Connector And Fuel Gauge Sending Unit 4P Connector
Courtesy of AMERICAN HONDA MOTOR CO., INC.
Is there continuity?
YES -Go to step 9.
NO -Repair an open or high resistance in the wire.
- Do the fuel gauge sending unit test (see
FUEL GAUGE SENDING UNIT TEST
).
Is the fuel gauge sending unit OK?
YES -Replace the gauge control module (see GAUGE CONTROL MODULE REPLACEMENT ).
NO -Replace fuel gauge sending unit (see FUEL PUMP/FUEL GAUGE SENDING UNIT REPLACEMENT ).
- Disconnect the fuel gauge sending 4P connector.
- Disconnect the secondary fuel gauge sending unit 4P connector.
- Check for continuity between fuel gauge sending unit 4P connector terminal No. 3 and secondary fuel gauge sending unit 4P connector terminal No. 1.Fig 2: Checking Continuity Between Fuel Gauge Sending Unit 4P Connector Terminal No. 3 And Secondary Fuel Gauge Sending Unit 4P Connector
Courtesy of AMERICAN HONDA MOTOR CO., INC.
Is there continuity?
YES -Go to step 13.
NO -Repair an open or high resistance in the wire.
- Disconnect the gauge control module 32P connector.
- Check for continuity between gauge control module 32P connector terminal No. 2 and fuel gauge sending unit 4P connector terminal No. 3.Fig 3: Checking Continuity Between Gauge Control Module 32P Connector And Fuel Gauge Sending Unit 4P Connector
Courtesy of AMERICAN HONDA MOTOR CO., INC.
Is there continuity?
YES -Go to step 15.
NO -Repair an open or high resistance in the wire.
- Check for continuity between gauge control module 32P connector terminal No. 4 and secondary fuel gauge sending unit 4P connector terminal No. 1.Fig 4: Checking Continuity Between Gauge Control Module 32P Connector And Secondary Fuel Gauge Sending Unit 4P Connector
Courtesy of AMERICAN HONDA MOTOR CO., INC.
Is there continuity?
YES -Go to step 16.
NO -Repair an open or high resistance in the wire.
- Do the fuel gauge sending unit test (see
FUEL GAUGE SENDING UNIT TEST
).
Is the fuel tank unit OK?
YES -Go to step 17.
NO -Replace fuel gauge sending unit (see FUEL PUMP/FUEL GAUGE SENDING UNIT REPLACEMENT ).
- Do the secondary fuel gauge sending unit test (see
SECONDARY FUEL GAUGE SENDING UNIT TEST
).
Is the secondary fuel gauge sending unit OK?
YES -Replace the gauge control module (see GAUGE CONTROL MODULE REPLACEMENT ).
NO -Replace the secondary gauge sending unit (see SECONDARY FUEL GAUGE SENDING UNIT REMOVAL/INSTALLATION ).