Calibration Procedure
The outside air temperature indicator's displayed temperature can be recalibrated ±5 °F (or ±3 °C) to meet the client's expectations.
- Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode.
- Push and hold the INFORMATION button for at least 3 seconds to enter the customizing mode.
- While in the customizing mode, select "CHG SETTING", and enter "METER SETUP". Then select "ADJUST OUTSIDE TEMP. DISPLAY", and calibrate the value with the SEL/RESET switch and the INFORMATION switch.
- When the desired correction value appears on the display, release the button, and the recalibrated outside air temperature will be displayed.NOTE: The recalibration temperature is not the value the sensor sees. Therefore the temperature can only be adjusted ±5 ° from the sensors reading.
Example:
Incorrect value = 68°F (20°C)
Desired correction value = +2°F (+ 1 °C)
Correct value = 70 °F (21 °C)
Desired correction value = -2 °F (-1 °C)
Correct value = 66 °F (19 °C)
NOTE: To recalibrate the display to the true temperature, remove the outside air temperature sensor (A), but leave it connected. Submerge the sensor and a thermometer (B) in a container of ice water (C). Select the calibration mode as described above, then recalibrate the display to the true temperature. - The snow mark is displayed when the temperature is 37 °F (3 °C) or less the first time you turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode.