Entering the Self-diagnostic Function

Before doing the self-diagnostic function, check the No. 7 (10 A) fuse and the No. 21 (7.5 A) fuse in the under-dash fuse/relay box.

  1. Push and hold the SEL/RESET button.
  2. Turn the headlights ON.
  3. Turn the ignition switch to ON (II).
  4. Within 5 sec, turn the headlights OFF, then ON and OFF again.
  5. Within 5 sec, release the SEL/RESET button, and then push and release the button three times repeatedly.
NOTE:
  • While in the self-diagnostic mode, the dashlights brightness controller operates normally.
  • While in the self-diagnostic mode, the SEL/RESET button is used to start the Beeper Drive Circuit Test and the Gauge Drive Circuit Check.
  • If the vehicle speed exceeds 1.2 mph (2 km/h) or the ignition switch is turned to LOCK (0), the self-diagnostic mode ends.
Fig 1: Identifying Blinking Screen
G08055473Courtesy of AMERICAN HONDA MOTOR CO., INC.