DTC B1192: Gauge Control Module Lost Communication With the Battery Sensor (UART LINE)
- Clear the DTCs with the HDS.
- Wait for at least 15 seconds.
- Check for DTCs with the HDS.
Is DTC B1192 indicated?
YES -Go to step 4.
NO -Intermittent failure, the battery sensor is OK at this time.
- Check the No. 9 (7.5 A) fuse in the main under-hood fuse box.
Is the fuse OK?
YES -Go to step 5.
NO -Replace the fuse, and recheck the system. If the fuse is blown again, repair a short in the wire.
- Turn the ignition switch to LOCK (0)
- Disconnect the battery sensor 2P connector.
- Measure the voltage between battery sensor 2P connector terminal No. 2 and body ground.
Courtesy of AMERICAN HONDA MOTOR CO., INC.
Is there battery voltage?
YES -Go to step 8.
NO -Repair an open in the wire between the main under-hood fuse box and the battery sensor.
- Disconnect gauge control module connector B (24P).
- Measure the voltage between battery sensor 2P connector terminal No. 1 and body ground.
Courtesy of AMERICAN HONDA MOTOR CO., INC.
Is there voltage?
YES -Repair a short to power in the wire between the gauge control module and the battery sensor.
NO -Go to step 10.
- Check for continuity between battery sensor 2P connector terminal No. 1 and body ground.
Courtesy of AMERICAN HONDA MOTOR CO., INC.
Is there continuity?
YES -Repair a short to ground in the wire between the battery sensor and the gauge control module.
NO -Go to step 11.
- Check for continuity between battery sensor 2P connector terminal No. 1 and gauge control module connector B (24P) terminal No. 7.Fig 4: Checking Continuity Between Battery Sensor 2P Connector And Gauge Control Module Connector B (24P)
Courtesy of AMERICAN HONDA MOTOR CO., INC.
Is there continuity?
YES -Substitute a known-good battery sensor, and recheck. If the DTC returns, replace the gauge control module
NO -Repair an open in the wire between the battery sensor and the gauge control module.