LEMON Manuals: Even more car manuals for everyone
Home >> Acura >> 2010 >> ZDX V6-3.7L >> Repair and Diagnosis >> Starting and Charging >> Starting System >> Testing and Inspection >> Symptom Related Diagnostic Procedures >> Engine Cranks, But Does Not Start >> Without Keyless Access System

Without Keyless Access System




Engine cranks, but does not start

Check for PGM-FI DTCs Initial Inspection and Diagnostic Overview.

Check for IMMOBI status and function Engine Does not Start With the Immobilizer Key.

Check the fuel pressure Testing and Inspection.

Check for a plugged or damaged fuel line Testing and Inspection.

Check for a plugged fuel filter Service and Repair.

Check the throttle body Testing and Inspection.

Check for low engine compression Testing and Inspection.

Check for a damaged or broken timing belt Testing and Inspection.

Do the powertrain control module (PCM) reset in the PGM-FI INSPECTION menu to cancel ALL INJECTORS STOP with the Honda Diagnostic System (HDS).

Also check for

Fuel level in tank

Also check for

Weak or fouled spark plugs