LEMON Manuals: Even more car manuals for everyone
Home >> Acura >> 2010 >> ZDX V6-3.7L >> Repair and Diagnosis >> Powertrain Management >> Fuel Delivery and Air Induction >> Variable Induction System >> Variable Induction Control Actuator >> Service and Repair

Variable Induction Control Actuator: Service and Repair




IMT Actuator Replacement

1. Remove the engine cover Intake Manifold Removal/Installation.

2. Disconnect the IMT actuator connector (A).





3. Remove the bolts (B) and the IMT actuator (C).

4. Install the parts in the reverse order of removal with a new O-ring (D).