Temperature Liquid Line Same Both Sides Expansion Valve, Evaporator Coil or Suction Line Has Heavy Condensation




The temperature of the liquid line is the same on both sides of the expansion valve, and the evaporator coil or suction line has heavy condensation

Probable cause: The expansion valve is stuck open.

Replace the expansion valve Service and Repair.

Also check for

Climate control DTCs Initial Inspection and Diagnostic Overview

Also check for

Check the old expansion valve for contamination. If contaminants are found, replace the A/C system component that caused the contamination.