LEMON Manuals: Even more car manuals for everyone
Home >> Acura >> 2010 >> TSX L4-2.4L >> Repair and Diagnosis >> Transmission and Drivetrain >> Automatic Transmission/Transaxle >> Shift Interlock >> Testing and Inspection >> Symptom Related Diagnostic Procedures

Symptom Related Diagnostic Procedures




Ignition switch cannot be moved from ACCESSORY (I) to LOCK (0) (key is pushed in, the shift lever in P)

Diagnostic Procedure:

1. Interlock control system circuit

2. Key interlock solenoid stuck ON

3. Park pin switch stuck OFF

4. Transmission range switch defective or out of adjustment

Also check for:

- Troubleshoot the key interlock system circuit. Key Interlock System Circuit Troubleshooting
- Inspect the transmission range switch. Testing and Inspection