Immobilizer Indicator Does Not Go OFF or Does Not Come ON (With Keyless Access System)




Keyless Access System Symptom Troubleshooting - Immobilizer indicator does not go off or does not come on

Immobilizer indicator does not go off or does not come on

1. Press the engine start/stop button to select the OFF mode.

2. Press the engine start/stop button to select the ON mode.

3. Check the immobilizer indicator.

Does the immobilizer indicator come on?

YES -

Go to step 4.

NO -

Go to step 9.

4. Check the immobilizer indicator.

Does the indicator come on, then go off?

YES -

Go to step 5.

NO -

Go to step 10.

5. Press the engine start/stop button to select the OFF mode.

6. Insert the remote into the remote slot.

7. Press the engine start/stop button to select the ON mode.

8. Check the immobilizer indicator.

Does the indicator blink once, then stay off?

YES -

Intermittent failure, the system is OK at this time.�

NO -

Go to step 12.

9. Check the malfunction indicator lamp (MIL).

Does the indicator come on?

YES -

Troubleshooting the ECM/PCM DTCs.�

NO -

Replace the gauge control module Service and Repair.�

10. Select KEYLESS ACCESS CONTROL UNIT from the ONE-PUSH START system select menu with HDS, and enter KEYLESS ACCESS CONTROL UNIT INFORMATION.

11. Do the SYSTEM CHECK 1 and 2 with the HDS.

Is N-1 OK indicated?

YES -

Replace the gauge control module Service and Repair.�

NO -

Troubleshoot the keyless access system according to the result of the SYSTEM CHECK 1 and 2 Keyless Access System Symptom Troubleshooting Information.�

12. Select REMOTE SLOT CONTROL UNIT from the ONE-PUSH START system select menu with HDS, and enter KEYLESS ACCESS CONTROL UNIT INFORMATION.

13. Do the SYSTEM CHECK with the HDS.

Is N-1 OK indicated?

YES -

Replace the gauge control module Service and Repair.�

NO -

Troubleshoot the keyless access system according to the result of the SYSTEM CHECK Keyless Access System Symptom Troubleshooting Information.�