Enable Conditions
ENABLE CONDITIONS REFERENCE CHART
| Condition | Minimum | Maximum | ||
|---|---|---|---|---|
| Elapsed time after starting the engine** | 10 seconds | - | ||
| Engine coolant temperature(1) | 131°F (55°C) | - | ||
| Battery voltage(1) | 10.5 V | - | ||
| Fuel feedback | Closed loop | |||
| No active DTCs | P0101, P0102, P0103, P0107, P0108, P0117, P0118, P0134, P0135, P0300, P0301, P0302, P0303, P0304, P0335, P0339, P0351, P0352, P0353, P0354, P0443, P0451, P0452, P0453, P0496, P0497, P0498, P0499, P1109, P1128, P1129, P1157, P1172, P145C, P2195, P2227, P2228, P2229, P2238, P2252, P2279 | |||
| Others** | The EVAP canister vent shut valve has not been closing | |||
| Stopping the purge control | ||||
|
||||