ENABLE CONDITIONS REFERENCE CHART

Condition Minimum Maximum
Elapsed time after starting the engine** 10 seconds -
Engine coolant temperature(1) 131°F (55°C) -
Battery voltage(1) 10.5 V -
Fuel feedback Closed loop
No active DTCs P0101, P0102, P0103, P0107, P0108, P0117, P0118, P0134, P0135, P0300, P0301, P0302, P0303, P0304, P0335, P0339, P0351, P0352, P0353, P0354, P0443, P0451, P0452, P0453, P0496, P0497, P0498, P0499, P1109, P1128, P1129, P1157, P1172, P145C, P2195, P2227, P2228, P2229, P2238, P2252, P2279
Others** The EVAP canister vent shut valve has not been closing
Stopping the purge control