LEMON Manuals: Even more car manuals for everyone
Home >> Acura >> 2009 >> MDX V6-3.7L >> Repair and Diagnosis >> Restraints and Safety Systems >> Air Bag Systems >> Testing and Inspection >> Symptom Related Diagnostic Procedures >> Side Airbag Cutoff Indicator Does Not Come On >> Symptom Troubleshooting

Symptom Troubleshooting




Symptom Troubleshooting: Side airbag cutoff indicator does not come on

Side airbag cutoff indicator does not come on

NOTE: If the SRS indicator also stays on, go to SRS indicator stays on, but no DTCs are stored. Symptom Troubleshooting

1. Turn the ignition switch to ON (II), and check that the side airbag cutoff indicator comes on for about 6 seconds.

Does the side airbag cutoff indicator come on?
YES - Go to the Symptom Troubleshooting "SRS indicator stay on."

NO - Go to step 2.


2. Connect the HDS to the DLC. Initial Inspection and Diagnostic Overview

3. Make sure the HDS communicates with the vehicle and the SRS unit. If it does not troubleshoot the DLC circuit. Testing and Inspection

4. Do the gauge control module self diagnostic function. Reading and Clearing Diagnostic Trouble Codes

Does the side airbag cutoff indicator come on?
YES - Faulty SRS unit; replace the SRS unit. SRS Unit Replacement

NO - Faulty gauge control module; replace the gauge control module. Service and Repair