LEMON Manuals: Even more car manuals for everyone
Home >> Acura >> 2009 >> MDX V6-3.7L >> Repair and Diagnosis >> Instrument Panel, Gauges and Warning Indicators >> Clock >> Description and Operation

Clock: Description and Operation




Clock System Description

Clock Operation

The clock shows day, date, and time information on the center information display. If the clock display does not appear normal, use the self-diagnosis function to test it.

Self-diagnosis function Mode 1 and Mode 2 force all possible segments on. If any of the segments do not appear as illustrated, the clock is faulty. Mode 3 forces all segments off. If there are any segments appearing, the clock is faulty.

If the clock is faulty, replace the center information display. Center Information Display Input Test

Self-diagnosis Function

1. Press and hold the "SET" button, the "v" arrow down button, and the "^" arrow up button, then turn the ignition switch to ON (II).

2. Release all buttons after 1 second.

3. Within 3 seconds, press and release the "SET" button, press and release the "v" arrow down button, and finally press and release the "^" arrow up button.

4. The self-diagnosis function begins with a blank display. Press and release the "^" arrow up button to scroll through the three modes.

5. Press the "SET" button to exit the self-diagnosis function.