EVAP Canister Vent Shut Valve Replacement

1. Remove the EVAP canister.




2. Pry the lock tabs outward (A), then remove the EVAP canister vent shut valve (B).

NOTE: Be careful not to damage the lock tabs.

3. Install the parts in the reverse order of removal with a new O-ring (C).