Outside Air Temperature Indicator Test: Calibration
The outside air temperature indicator's displayed temperature can be recalibrated ± 3° to meet the client's expectations.
('04-05 models)
- Turn the ignition switch ON (II).
- Press and hold the reset select button for 10 seconds. While you continue to hold the button, the display will scroll through temperature settings between +3° and -3° as shown.
- When the desired correction value appears on the display, release the button, and the recalibrated outside air temperature will be displayed. Each time a desired correction value is entered, it replaces the previous value.
Example:
Incorrect value = 68 ° (20°C)
Desired correction value = +2°F(+1°C)
Correct value = 70°F (21°C)
Desired correction value =- 2°F(- 1°C)
Correct value = 66°F (19°C)
NOTE: To recalibrate the display to the true temperature, remove the outside air temperature sensor (A), but leave it connected. Submerge the sensor and a thermometer (B) in a container of ice water (C). Select the calibration mode as described above, then recalibrate the display to the true temperature.
('06-08 models)
- Unlock the driver's door by using the keyless transmitter.
- Turn the ignition switch ON (II).
- Press and hold the INFO switch for more than 3 seconds.
- Select "CHANGE SETTING" on the multi-information display (MID).
- Select "METER SETUP", and then "ADJUST OUTSIDE TEMP, DISPLAY".
- Press the INFO switch repeatedly. When the desired correction value is shown on the MID, press the SEL/RESET switch.
- The correction value is displayed for several seconds, and then the display goes back to "CUSTOMIZE MENU".
Example:
Incorrect value = 68°F (20°C)
Desired correction value = +2°F (+1°C)
Correct value = 70°F (21°C)
Desired correction value = -2°F (- 1°C)
Correct value = 66°F (19°C)
NOTE: To recalibrate the display to the true temperature, remove the outside air temperature sensor (A), but leave it connected. Submerge the sensor and a thermometer (B) in a container of ice water (C). Select the calibration mode as described above, then recalibrate the display to the true temperature.