B2602
CIRCUIT DESCRIPTIONThe Body Control Module (BCM) controls the DRL relay by grounding the control circuit of the DRL relay coil.
CONDITIONS FOR RUNNING THE DTC
^ Voltage supplied to the module is in the normal operating voltage range (approximately 10-16 volts).
^ The DRL feature must be enabled.
CONDITIONS FOR SETTING THE DTC
^ The BCM detects a short to ground or an open in the control circuit of the DRL relay coil when the daytime running lamps are inactive.
^ The condition must be present for more than 3 ms.
ACTION TAKEN WHEN THE DTC SETS
^ The BCM stores DTC B2602 in memory.
^ The SERVICE VEHICLE SOON telltale illuminates.
CONDITIONS FOR CLEARING THE DTC
^ A current DTC B2602 clears if the BCM no longer detects a short to ground or an open in the control circuit of the DRL relay coil.
^ A history DTC B2602 clears after 100 consecutive ignition cycles.
^ The BCM receives the Clear Code commend from the scan tool
DIAGNOSTIC AIDS
^ If the DTC B2602 is a history DTC the fault may be intermittent. Refer to Testing for Intermittent and Poor Connections in Diagrams.
^ An intermittent short to ground or an open in the following locations may cause an intermittent malfunction to occur:
- The control circuit of the DRL relay coil
- The DRL relay
- The BCM
TEST DESCRIPTION
Steps 1-13:
The number(s) below refer to the step number(s) on the diagnostic table.
2. Listen for an audible click when the DRL relay operates. Command both the ON and OFF states. Repeat the commands as necessary.
3. This step tests for voltage at the coil side of the DRL relay.
4. This step verifies that the Body Control Module (BCM) is providing ground to the DRL relay.
5. This step tests whether ground is constantly being applied to the DRL relay.
6. This step tests for a short to battery voltage.