LEMON Manuals: Even more car manuals for everyone
Home >> Chevrolet >> 2000 >> Venture V6-3.4L VIN E >> Repair and Diagnosis >> Heating and Air Conditioning >> Testing and Inspection >> Symptom Related Diagnostic Procedures >> Defrosting Insufficient

Defrosting Insufficient

1. Inspect for an obstruction in both of the defroster nozzles.
Perform the following steps, as necessary:
^ Remove any foreign objects.
^ Repair any loose instrument panel pad that blocks an outlet.
2. Inspect for the proper operation of the defroster air valve.
3. Inspect for one of the following conditions. Replace the defroster vacuum actuator or hose if one of the following conditions exist:
^ A faulty defroster air valve vacuum actuator
^ A faulty defroster air valve vacuum hose
4. Inspect for insufficient heating. Refer to Heating Insufficient. Heating Insufficient