REMOVAL PROCEDURE
1. Turn the ignition OFF.




2. Remove the camshaft position (CMP) actuator valve electrical connector.




3. Remove the CMP actuator valve bolt.
4. Remove the CMP actuator valve.

INSTALLATION PROCEDURE




1. Install the CMP actuator valve.
2. Install the CMP actuator valve bolt.

NOTE: Refer to Fastener Notice in Service Precautions.

Tighten the CMP actuator valve bolt to 10 Nm (89 lb in).




3. Install the CMP valve electrical connector.